The HAAS VF-2 Vertical Machining Center requires training. Nothing else in the machine shop requires training, however members should not use any equipment without understanding its operational and safety requirements. Manuals and some video tutorials are available on the page. If you require help with using equipment, send an email to Training for the HAAS VF-2 is is offered to members on a regular basis; see the event calendar for details. Once trained, members will be allowed to use the CNC mill only under supervision, until they have demonstrated their proficiency in its operation. Training is not required for the use of the Bridgeport Mill, but a basic course in the operation of the mill is regularly offered. This class is broken into two sections, and in classroom session that covers controls, safety, etc.

Haas Vf2 Manual

And a second session with some hands on demonstration. Dylan's 'Tool Setup' -Get block indicator and position on table -Push MDI DNC -Type G128 then push WRITE/ENTER -Push START -Push HANDJOG -Push OFFSET and page up or down to get to the tool list -Push Z-axis -Jog down until indicator reads zero -Make sure cursor is over the right tool number under GEOMETRY -Push TOOL OFFSET MEASUR -Check to make sure the new Measurement is 5in.

Tripped Breaker/GFI Plug Corrective Action:. Check if CB6 1 (CHC) or CB2 (NGC) on the PDIST PCB has been tripped. Reset the circuit breaker if necessary.

Disconnect anything that is connected to the GFCI receptacle. Push the RESET button on the GFCI receptacle. Measure the voltage at the plug. The voltage must measure 120 VAC when the RESET button is fully engaged. If the RESET button does not fully engage, disconnect the light cable:. Work light: I/O PCB P36 (CHC) or P18-21 (NGC).

HIL: I/O PCB P36A (CHC) or P22 (NGC). Push the RESET button on the GFCI receptacle again. If the RESET button fully engages and you have 120 VAC, the GFI plug is working correctly. Find the cause of the short in the light circuit by checking the cable and fixtures. If the RESET button does not fully engage, the GFCI receptacle is defective.

Replace the GFCI receptacle. After you replace the GFCI, if there is still no voltage, go to. Bulb/Fixture Corrective Action:. Fluorescent light: Check for burn marks on the bulb. Stihl 045 av super specs.

Check for 120 VAC at the fixture connector. If voltage is correct, test the bulb in another fixture.

If the bulb works in another fixture, unplug the non-working fixture and check for contamination or damage. Replace the fixture or bulb as needed. Halogen light: Check for burn marks on the bulb.

Haas vf5 service manual

Check for 120 VAC at the lamp head connector. If the voltage is correct, test the bulb in another lamp head. If the bulb works in another lamp head, unplug the non-working unit and check for damage. Replace the lamp head or bulb as needed. LED light: Check for 120 VAC at the fixture connector. If the voltage is correct, and the LED does not work, it must be replaced.

Haas Vf3 Maintenance

If the LED is flickering on and off, re-seat the connections. If flickering continues, replace the LED assembly.